Equipment error code
Trane code 2 flashes
Two flashes — pressure switch stuck open. The inducer ran but the pressure switch did not close to prove draft within the time allowed.
- Equipment
- furnace
- Brand
- Trane
- Source checked
- 2026-03-01
What this code means
Two flashes — pressure switch stuck open. The inducer ran but the pressure switch did not close to prove draft within the time allowed.
Which models show it
Trane induced-draft furnaces including XV80, XV90, S9X1, S9V2, XC80, and XC95 with standard LED diagnostics.
What is actually happening
Inducer runs, no ignition. The board waits for pressure switch closure, times out, and blinks two flashes.
Is it safe to keep running?
Heating is usually inhibited. Fix venting before forcing retries — a stuck-open switch can also mean no draft.
Shut it down when
Exhaust smell in the mechanical room, iced intake/outtake you cannot clear safely, or water pouring from the condensate assembly.
What a homeowner can safely check
- Clear snow and debris from outdoor PVC intake and exhaust terminations.
- Inspect pressure switch hoses for cracks or disconnects at the inducer housing.
- Empty the condensate trap on 90%+ furnaces.
- Listen for a grinding inducer — bearing failure reduces draft.
When to stop
- Roof-line vents you cannot reach safely.
- Repeated 2-flash after hoses and trap service.
- Suspected heat exchanger or collector leak.
Likely causes ranked
1. Blocked or improperly sloped vent piping
How a tech confirms: Combustion analyzer and draft measurement; compares install to Trane vent tables.
Typical repair: $200–$500 · Air Conditioner Repair cost guide
2. Failed pressure switch
How a tech confirms: Vacuum test at switch ports; replacement with OEM switch.
Typical repair: $185–$400 · Air Conditioner Repair cost guide
3. Weak inducer motor
How a tech confirms: Amp draw and wheel inspection; replaces motor assembly if below spec.
Typical repair: $375–$875 · Furnace Replacement cost guide
4. Condensate blockage in collector box
How a tech confirms: Inspects collector and drain path; pressure tests secondary circuit.
Typical repair: $225–$550 · Air Conditioner Repair cost guide
Is this the end of this unit?
Major vent rework or secondary exchanger issues on older Trane units can approach replacement cost — get a written heat exchanger inspection result.
How to clear the code
After clearing vents and condensate, power cycle the furnace once. Watch for inducer start and switch click before ignition.
Why clearing is not fixing it: Two flashes return until draft is proven. A cleared code with a failed switch or motor fails again on the next call for heat.
Which trade to call
Call a licensed hvac contractor who works on furnace equipment. Gas, refrigerant, and combustion faults are not general handyman jobs.
Related codes and symptom guides
More codes from this brand
Symptom guide: Furnace Not Heating
FAQ
What does 2 flashes mean on Trane?
Can snow block cause Trane 2 flash?
Is the pressure switch a DIY part?
Typical cost for 2-flash repair?
2 flashes vs Carrier code 31?
Source
Source — Trane S9X1/S9V2 Service Facts — Status Light Flash Codes (18-HD64D1-1). Checked .