Equipment error code
Lennox code E201
E201 — low flame signal. Flame was detected but below the minimum microamp threshold required to hold the gas valve open.
- Equipment
- furnace
- Brand
- Lennox
- Source checked
- 2026-03-01
What this code means
E201 — low flame signal. Flame was detected but below the minimum microamp threshold required to hold the gas valve open.
Which models show it
Lennox SLP98V, EL296V, SL280V, ML193, and compatible furnaces reporting numeric E-codes on display or iComfort.
What is actually happening
Burners may light weakly then shut off, or never stay lit long enough to heat. The board drops flame proof and logs E201.
Is it safe to keep running?
Avoid repeated heat calls. Weak flame can produce carbon monoxide — ventilate if you smell exhaust.
Shut it down when
Yellow or floating flames, soot, or E201 more than twice after one reset.
What a homeowner can safely check
- Confirm gas shutoff is on and other gas appliances work.
- Replace a heavily soiled filter.
- Ensure combustion air grilles are not blocked in utility rooms.
- Power cycle once after checks — not repeatedly.
When to stop
- Gas odor.
- Visible soot or discoloration at burners.
- E201 returns within one cycle.
Likely causes ranked
1. Dirty or misaligned flame sensor
How a tech confirms: Microamp test; cleans and positions rod per Lennox spec.
Typical repair: $155–$340 · Air Conditioner Repair cost guide
2. Low gas pressure or meter issue
How a tech confirms: Manometer at valve; coordinates with utility if supply-side.
Typical repair: $180–$450 · Air Conditioner Repair cost guide
3. Weak igniter or delayed ignition
How a tech confirms: Ignition timing observation; replaces HSI if out of range.
Typical repair: $210–$490 · Furnace Replacement cost guide
4. Cracked heat exchanger causing flame disturbance
How a tech confirms: Heat exchanger inspection; combustion spillage test.
Typical repair: $3,600–$7,900 · Furnace Replacement cost guide
Is this the end of this unit?
E201 with confirmed exchanger damage means furnace replacement — flame signal fixes alone will not make a cracked chamber safe.
How to clear the code
Single power cycle after gas and filter checks. Wait five minutes before a new heat call to allow purge timers.
Why clearing is not fixing it: Low microamps return whenever the sensor, gas pressure, or combustion path is still marginal.
Which trade to call
Call a licensed hvac contractor who works on furnace equipment. Gas, refrigerant, and combustion faults are not general handyman jobs.
Related codes and symptom guides
More codes from this brand
Symptom guide: Furnace Not Heating
FAQ
What does Lennox E201 mean?
Is E201 the same as no ignition?
Can I clean the flame rod for E201?
E201 repair costs?
Does iComfort show E201 history?
Source
Source — Lennox EL296V Installation Instructions — Fault Code Table (EHB-EL296V-01). Checked .