Carrier code 31
Pressure switch did not close (or did not open when expected) — the control monitored the inducer and pressure switch circuit and found the switch state out of sequence with the ignition chart.
- Equipment
- furnace
- Brand
- Carrier
- Source checked
- 2026-03-01
What this code means
Pressure switch did not close (or did not open when expected) — the control monitored the inducer and pressure switch circuit and found the switch state out of sequence with the ignition chart.
Which models show it
Carrier/Bryant condensing and mid-efficiency furnaces with induced draft — 59MN7, 59TN6, 59SC5A, 58MCA, 58MVP, and related 59SP series.
What is actually happening
The inducer may run continuously or the furnace may never advance to ignition because the board does not see the pressure switch change state. Heat never starts or stops early.
Is it safe to keep running?
A pressure fault usually prevents ignition, so the furnace will not heat. Running repeated reset cycles stresses the inducer motor without fixing venting.
Shut it down when
Stop if you hear the inducer laboring, smell exhaust in the utility room, or see water backing up in the condensate line on a 90%+ furnace.
What a homeowner can safely check
- Inspect the small rubber hoses from the inducer to the pressure switch — disconnected hoses are a common find.
- On high-efficiency units, clear the condensate trap — a full trap can prevent the switch from closing.
- Check the exhaust and intake PVC outside for ice, nests, or snow blockage (keep 12+ inches clear).
- Confirm the furnace intake and exhaust are not capped or swapped after service.
When to stop
- Ice or debris you cannot safely clear from roof-line terminations.
- Suspected flue corrosion or condensate leaking inside the cabinet.
- Code 31 persists after hoses are reconnected and trap cleared.
Likely causes ranked
1. Blocked vent or intake (ice, debris, improper termination)
How a tech confirms: Measures draft and combustion air; inspects vent length and fittings against installation manual.
Typical repair: $175–$450 · Air Conditioner Repair cost guide
2. Failed pressure switch or stuck diaphragm
How a tech confirms: Applies calibrated vacuum to switch terminals; replaces switch if opens/closes out of spec.
Typical repair: $200–$425 · Air Conditioner Repair cost guide
3. Weak or failed inducer motor
How a tech confirms: Measures inducer amp draw and RPM; inspects wheel for cracks or debris.
Typical repair: $350–$850 · Furnace Replacement cost guide
4. Cracked condensate collector or blocked secondary heat exchanger
How a tech confirms: Pressure tests collector; inspects secondary for blockage on condensing models.
Typical repair: $400–$1,200 · Furnace Replacement cost guide
Is this the end of this unit?
Secondary heat exchanger or inducer failures on furnaces over 15 years often push replacement math. Compare repair quotes to a new high-efficiency furnace install.
How to clear the code
Clear vent blockages and condensate, reconnect hoses, then power cycle once. Allow the inducer to run through its pre-purge before expecting ignition.
Why clearing is not fixing it: The switch must prove draft before ignition. Clearing the code without restoring venting or switch function brings code 31 back immediately.
Which trade to call
Call a licensed hvac contractor who works on furnace equipment. Gas, refrigerant, and combustion faults are not general handyman jobs.
Related codes and symptom guides
More codes from this brand
Symptom guide: Furnace Not Heating
FAQ
What does Carrier furnace code 31 mean?
Can a clogged condensate line cause code 31?
Is code 31 dangerous?
How much does fixing code 31 cost?
Why does the inducer run but nothing else happens?
Source
Source — Carrier 59MN7 Service Instructions — Fault Code Definitions (099-35-04PY-0A). Checked .